2023年7月17日星期一

Which factors affect motor performance changes?

             What's the factor affect 

               DC motor   

       performance change


The Main factors that affecting micro DC motor performance changes


What's the factor affect motor performance change

The performance of a motor is determined by three major factors: 

  1. voltage between terminals
  2. resistance between terminals
  3. magnetic force.

Here, we will provide specific examples to illustrate the various main factors that have an impact on these main factors, namely the deterioration of DC motor performance.

Voltage for  DC motor performance changes:

Only when there is a change in the voltage of the power supply can the performance be directly proportional to the change in voltage.

As shown in the image, when the voltage changes due to the power supply, the rotating line moves in Parallel transport, and the current line almost changes in a straight line. 

However, beyond a certain limit, it is no longer proportional to the voltage.

What's the factor affect DC motor performance change














Power type for DC motor perfomance change:

Comparing a Constant power supply with an attached resistance power supply (a power supply with internal resistance r), 

the attached resistance power supply will experience a voltage drop with the internal resistance r.

The stopping current will initially decrease, and the stopping torque will also decrease, causing a change in the inclination of the rotating line.

What's the factor affect DC motor performance change

Internal resistance of manganese battery (1.5V)

Unit 1 type

0.15~0.20 (Ω)

Unit 2 type

0.25~0.35 (Ω)

Unit 3 type

0.40~0.50 (Ω)


Remarks:A motor can be defined by a generator that generates a voltage proportional to the number of revolutions, as well as a motor terminal resistance in series with the voltage.

Coil for  motor perfomance change:

What has a significant impact on motor performance is the coil size.


When there is a change in the number of coils and the diameter of the coil, the results are different.

If the number of coils is increased, the no-load speed of the motor will decrease proportionally.

What's the factor affect DC motor performance change

If the diameter of the coil is thickened, the stopping torque and stopping current of the motor increase proportionally to the square of the coil diameter. 

However, beyond a certain limit, it is no longer proportional to the square.

What's the factor affect DC motor performance change

Conditions for changing the winding line with the same model


When changing the winding line with a motor of the same model, it is necessary to use similar line product values.


Line product value= φ 2 (twice the diameter of the coil wire) × N (number of coils)


Temperature for  motor perfomance change:

The ambient temperature can affect the magnetic force and coil resistance of the magnet. Therefore, there will also be changes in motor performance.


What's the factor affect DC motor performance change

The degree of change at every 1 ℃ change

 

The magnetic force of a magnet

ferrites

-0.19%


Rare earth magnet

-0.13%

Coil resistance

+0.39%

Additional explanation: The impact on the 4-point performance of the motor when the temperature increases


N0: No load RPM


In inverse proportion to the weakening of the magnetic force of the magnet, N0 increases.


I0: No load current


It is inversely proportional to the magnetic force of the magnet, but the loss caused by changes in the viscosity of the bearing oil has a greater impact on I0. 

Therefore, our company assumes that I0 is not affected by temperature changes when making presumptive calculations.


Is: stopping current


Inversely proportional to the coil resistance, if the temperature rises, Is will decrease.


Ts: Stopping torque


Due to the weakening of the magnetic force of the magnet, the current will decrease. Therefore, if the temperature rises, Ts will significantly decrease.


List of Main Factors for Returning to Changes


Types of magnets for motor performance change


There are also various types of magnets, mainly referring to changes in magnetic force.


Because when changing from a wet heterojunction magnet to a dry heterojunction magnet, the magnetic force will weaken,

 causing a decrease in the stopping torque (Ts) and an increase in the number of unloaded rotations (N0).

What's the factor affect DC motor performance change

case for for motor performance change

In terms of the ability of magnets, when the metal shell that maintains the magnetic force is thin, 

the magnetic force will leak out of the shell. The so-called auxiliary casing refers to preventing magnetic leakage in order to ensure the ability of the magnet.


The value of a will vary depending on the leakage degree of the motor's magnetic force or the thickness of the auxiliary casing. 

The difference in the auxiliary casing in our company is approximately 8-12%, and it is considered as a=1.08-1.12.

What's the factor affect DC motor performance change

Phase for for motor performance change



Phase refers to the position relationship between the conversion position of the commutator and the brush and the center position of each magnetic pole of the magnet.


Even if the motor is assembled into a neutral phase in the early stages, during load operation, due to the phenomenon of rotor reaction,

 it will become delayed phase (delayed angle) electrically for a period of time. Delayed angle is a poor condition for motors, 

which will lead to deterioration in efficiency, electrical noise, lifespan, and other aspects. 

As an improvement measure, the phase angle is assembled into an inlet angle, 

which counteracts the rotor reaction during load rotation to maintain a neutral inlet angle motor electrically.




Set the neutral 4-point performance to (N0, I0, Is, Ts), and the performance of the inlet angle to (N0 ', I0', Is', Ts'). 

The performance of the inlet angle will be as shown in the above figure, with a slight increase in no-load speed N0 ', 

while other performance is generally similar. When the variation of N0 'is 12-15 °, the angle of entry is 6-8%.


However, when calculating Ts based on the intermediate torque performance, the angle of entry may become relatively small.


What's the factor affect DC motor performance change


Points to note about the angle motor


If the angle motor is reversed in this state, it will become a delayed angle, leading to deterioration of the rectification effect, 

and adverse factors in terms of electrical noise and lifespan. Therefore, the direction of rotation must be unidirectional.


More information of DC motor,pls refer to:

DC motor overview


2023年7月6日星期四

spring contact 6mm vibration motor Z0610-TP

 6mm vibration motor Z0610-TP



                                          Spring vibration motor Z0610-TP

Spring contact,easy for assemble.


Vibration motor Z0610-TP drawing:

glucose meter motor,vibration motor


vibration motor Z0610-TP widely used for:

Medical equipment: intelligent kit, Sphygmomanometer, Glucose meter


Electric beauty products: beauty pens, electric facial cleaners, facial massagers, eye protectors

Electric toys: Model aircraft, Quadcopter, aircraft model, UAV

Vibrators: contact lens cleaning machines, electronic equipment vibrations, sex products, mobile phones and fields such as steering gear, precision instruments, robots, etc.


Vibrating Glocose meter motor characteristics:


  • rated voltage:1.5V;
  • no load current:7mA;
  • no load speed:8500r/min;
  • stall current:0.046A;
  • stall torque:0.64gf.cm

Accepting and providing customized micro dc motor consulting, design, and manufacturing services, we can offer suitable and high-quality DC micro motors for you.


Confidence comes from quality, and service highlights value. Dedicated to serving you!